Home > News > 6 troubleshooting methods for plastic mold laser welding machine

6 troubleshooting methods for plastic mold laser welding machine

2022-06-27

In the whole process of application of plastic mold Laser Welding Machine, there are more or less common faults, in order to make the laser welding machine work more stably, reduce the frequency of abnormalities and improve work efficiency, people must master its operation. Problems that should be paid attention to in the process and abnormal solutions.


1. The machine and equipment of the plastic mold pre-welding laser welding machine are abnormally terminated during operation: check the relevant alarms on the alarm interface of the touch screen display. If there is an alarm, the machine equipment will automatically switch to the pause state and the reset switch will flash at a frequency of 0.2s. In addition, the passive buzzer will beep at a frequency of 1s and the green light of the tri-color light will be on for a long time. After dealing with the relevant alarm, press the alarm reset switch to calibrate the alarm, and then press the start button to operate again;


2. When the electric welding of the plastic mold laser generator is incorrect, press and hold the emergency stop switch immediately, the system software will automatically disconnect the laser generator operation, and each AC servo motor switches the power supply to avoid accidents. reset the actual operation;


3. When the machine and equipment of the plastic mold pre-welding laser welding machine is out of position, please check whether there is an alarm on the touch screen or the machine and equipment is suspended or waiting for materials: the entire equipment calibration alarm: the plastic mold pre-welding laser welding needs to be calibrated Only the entire equipment can be operated;


4. Limit switch alarm: it indicates that the motor reaches the soft limit switch, and it only operates in the reverse direction without calibration;


5. Axis ALM alarm: just match the calibration axis alarm in the action dialog box or press the alarm reset switch;


6. When the laser will not be manipulated during operation, you need to quickly press and hold the emergency stop switch. Press and hold the direction change to stop pushing the laser data signal and turn off the power of the electric welding shaft. After solving common faults, pop up the emergency stop switch and start the plastic mold. The entire equipment of the pre-welding laser welding machine can be calibrated and the program flow can be run again.


Feiquan laser welding machine manufacturers analyzed 6 common fault solutions for plastic mold laser welding machines for everyone. I want to help everyone better solve problems in their work and improve work efficiency more reasonably.